Background

In the previous section, we have focused on mechanical artifacts and computational methods to correct them. In this section, we investigate optical artifacts that are due to refractive-index (RI) mismatch between the sample and the immersion liquid.

Motivation

During an OPT experiment, the sample is typically embedded in a cylindrical gel phantom which is immersed in an RI-matching liquid [11, 120, 121]. The purpose of this is to limit the refraction of light at the interface of the agarose gel and the immersion liquid [120, 121, 122, 123], in order for the assumption of straight-ray projections to be acceptable. Despite their best effort, OPT practitioners still observe seagull-shaped artifacts suspected to be caused by a residual mismatch in the RIs [13]. A previous study had already reported similar artifacts, mostly located around the edge of the sample, and proposed a computational method to compensate for RI mismatch [100]. However, as this method requires volumetric alignment, it remains computationally expensive.

Contribution

In this section, we propose a simple model based on ray optics to approximate the effect of RI mismatch, which we interpret as a virtual cylindrical lens and approximate the lensing effect with the help of a cone-beam model. We then implement a fast reconstruction method to correct resulting seagull-shaped artifacts and validate our approach on experimental data of fluorescent beads.